TDM96-5M |
|
 |
 |
 |
 |
| Released date:
2009/11/11 |
 |
| Category:
DIGITAL MULTIMETER |
 |
| Name:
96×96 5 Windows(3A/V/HZ) |
 |
|
|
| Introduction |
Display: 4 Windows, Red high efficiency LED high 9.14mm (.36") Accuracy: ±0.5% ±2digit Operating Condition: -10℃~50℃ (20% to 90% RH non-condensed) Dielectric Strength: AC 2KV/1min Aux. Power: AC110V/220V 50/60Hz Function: Display 3 Phase Current , 1 Phase Voltage, Frequency Simultaneously. Press key “V1/V2/V3” to switch voltage display among 3 phases. Measurement Range: Amperage: Direct measurement current AC 0-5A. For current above 5A, Current Transformer (C.T.) must e used. The following are the available C.T. Ratios: 10A/5A, 15A/5A, 20A/5A, 25A/5A, 30A/5A, 40A/5A, 50A/5A, 60A/5A, 70A/5A, 75A/5A, 80A/5A, 100A/5A, 120A/5A, 150A/5A, 160A/5A, 200A/5A, 250A/5A, 300A/5A, 400A/5A, 500A/5A, 600A/5A, 700A/5A, 750A/5A, 800A/5A, 1kA/5A, 1.2kA/5A, 1.5kA/5A, 1.6kA/5A, 2kA/5A, 2.5kA/5A, 3kA/5A, 4kA/5A, 5kA/5A, 6kA/5A, 7kA/5A, 7.5kA/5A, 8kA/5A. Note: Red LED indicates Ampere. Green LED indicates Kilo-ampere (kA) Voltage: AC 50-600V Frequency: 1-99.9Hz, Input voltage: AC50-600V |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
ASD-2N |
|
 |
 |
 |
| Released date:
2009/03/03 |
 |
| Category:
AC SOLENOIDS |
 |
| Name:
2 KG Rated Pull AC Solenoids |
 |
|
|
| Introduction |
Rated Pull (KG): 2.0 Rated Stoke (MM): 15 Frequency of Operation: 1200 Rated Voltage (AC): 24V, 36v, 110V, 220V, 380V |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
TCK-3 |
|
 |
 |
 |
| Released date:
2009/03/03 |
 |
| Category:
FLOATLESS SW & CONTROLLER |
 |
| Name:
96×96 Temperature Controller |
 |
|
|
| Introduction |
Supply Voltage: 110/220VAC 50/60HZ Operation Voltage: 90% to 110% of rated voltage Power Consumption: Approx ﹤2VA Terperature Sensor: K,E,J,T,PT-100 Standard Scale Range: 0-400 (DEGREE C) Setting Accuracy: ±1.5%max. of full scale Indication Accuracy: ±2.5%max. of full scale Hysteresis Control Output: 0.2% of full scale (fixed) PD setting range: Proportional hand (P)1-3%of full scale, Rate time (D)30±10S
STANDARD ACCESSORY: 1 Piece Thermocouple Wire, when temperature under 600 degree C (TCK) type. Thermocouple Wire Length: 2M |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
LHS-6 |
|
 |
 |
 |
| Released date:
2009/02/26 |
 |
| Category:
COUNTER & HOUR METER |
 |
| Name:
6 Digital Hour Counter (Short circuit input) |
 |
|
|
| Introduction |
Count Input: Contact input by short circuit Contact Resistance: (ON)≦10KΩ, (OFF)≧500KΩ Number of Count: 9999H59M Counting Speed: Signal width ≧1 SEC. Reset: Signal width ≧0.2 SEC.
|
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
MY4 |
|
 |
 |
 |
| Released date:
2009/03/04 |
 |
| Category:
RELAY/ TIMER & SOCKET |
 |
| Name:
MY Relay 4A4B |
 |
|
|
| Introduction |
Model: MY4, MY4NJ (with LED indicator) External Dimension(mm): (L)27.6×(W)21.5×(H)34 Contact Form: 4A4B Contact Capacity: 3A, 28VDC/220VAC Coil Voltage: DC6,12,24,48,110V/ AC6,12,24,48,110,220V Contact Resistance: ≦50mΩ Insulation Resistance: ≧1000mΩ Dielectric Strength: 1000AC 50/60Hz Service Life: (Mechanical) 10,000,000 / (Electrical) 100,000 Terminal: Outlet and printed – Circuit board |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
TBH45 |
|
 |
 |
 |
| Released date:
2009/11/24 |
 |
| Category:
24 HOURS TIME SWITCH |
 |
| Name:
NON POWER FAILURE 24H TIME SWITCH (100H) |
 |
|
|
| Introduction |
Rated Voltage: AC110V~250V (Common Use) Frequency: 45~60HZ Resistive Load: AC 250V 16A Minimum Setting Interval: 15 Minutes Back Up Power Memory: 150 Hours Mounting Methods: By 35mm DIN Rail |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|
PA60 |
|
 |
 |
 |
| Released date:
2009/02/26 |
 |
| Category:
WARNING LIGHT& MULTI-LAYER TOWER LIGHT |
 |
| Name:
60Ø Pilot Lamp type Tower Light |
 |
|
|
| Introduction |
Diameter: 60Ø Layer: 1~5 Color: Red, Green, Orange, Blue, White. Voltage: 12V, 24V, 110V, 220V. Bulb: Tungsten Lamp, LED Bulb Action: Pilot Lamp type |
|
| PDF Download |
CAD Download
|
|
|
|
|
|
|
|